4 message communication, Communi cat in g wit h the il seri es – KEYENCE DL-EP1 User Manual

Page 74

Advertising
background image

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -

3-4 Message Communication

3-44

3

Communi

cat
in

g wit

h the

IL Seri

es

Group4

038BH

(907)

Delay timer

Set up delay timer.

Parameter range: 0 to 3 (initial value: 0)

0:OFF

1:On delay

2:Off delay

3:One-shot

R/W

DINT

038CH

(908)

Timer duration

Set up timer duration (unit: ms).

Parameter range: 5 to 9999 (Initial value: 60)

R/W

DINT

038DH

(909)

Hysteresis

*2

Set up hysteresis.

Parameter range: 0.000 to 99.999

R/W

DINT

038EH

(910)

Analog output

scaling

*9

Set up analog output scaling. (Main unit only)

Parameter range: 0 to 1 (initial value: 0)

0:Initial state

1:Free range

2:Bank

R/W

DINT

038FH

(911)

Analog output -

upper limit

value

*2, *9

Set up upper limit of analog output.

Parameter range: -99.999 to 99.999

(Initial value: +10.000)

R/W

DINT

0390H

(912)

Analog output -

lower limit value

*2, *9

Set up lower limit of analog output.

Parameter range: -99.999 to 99.999

(initial value: -10.000)

R/W

DINT

0391H

(913)

External input

*10

Set up whether to change the function

assigned to external input 1/2/3/4 from the

initial state.

Parameter range: 0 to 1 (initial value: 0)

0:Initial state

1:User setting

R/W

DINT

0392H

(914)

External input 1

*10

Set up function to be assigned to external

input 1.

Parameter range: 0 to 4 (initial value: 0)

0:Zero shift input

1:Bank A input

2:Bank B input

3:Laser emission stop input

4:Not used

R/W

DINT

0393H

(915)

External input 2

*10

Set up function to be assigned to external

input 2.

Parameter range: 0 to 4 (initial value: 0)

0:Reset input

1:Bank A input

2:Bank B input

3:Laser emission stop input

4:Not used

R/W

DINT

0394H

(916)

External input 3

*10

Set up function to be assigned to external

input 3.

Parameter range: 0 to 4 (initial value: 0)

0:Timing input

1:Bank A input

2:Bank B input

3:Laser emission stop input

4:Not used

R/W

DINT

0395H

(917)

External input 4

*10

Set up function to be assigned to external

input 4.

Parameter range: 0 to 3 (initial value: 0)

0:Not used

1:Bank A input

2:Bank B input

3:Laser emission stop input

R/W

DINT

Class