Setup, Network wiring, Fm radio tuner crestron c2n-tfm – Crestron electronic C2N-TFM User Manual

Page 12

Advertising
background image

FM Radio Tuner

Crestron C2N-TFM

8

FM Radio Tuner: C2N-TFM

Operations Guide - DOC. 6233A

Setup

Network Wiring

CAUTION: Use only Crestron power supplies for Crestron equipment. Failure to
do so could cause equipment damage or void the Crestron warranty.

CAUTION: Provide sufficient power to the system. Insufficient power can lead to
unpredictable results or damage to the equipment. Please use the Crestron Power
Calculator to help calculate how much power is needed for the system.

http://www.crestron.com/dealer-tech_resources/power_calculator.asp

NOTE: When installing network wiring, refer to the latest revision of the wiring
diagram(s) appropriate for your specific system configuration, available from the
Downloads | Product Manuals | Wiring Diagrams section of the Crestron website
(

www.crestron.com

).

When calculating the wire gauge for a particular Cresnet run, the length of the run
and the power factor of each network unit to be connected must be taken into
consideration. If Cresnet units are to be daisy-chained on the run, the power factor of
each unit to be daisy-chained must be added together to determine the power factor
of the entire chain. If the unit is a home-run from a Crestron system power supply
network port, the power factor of that unit is the power factor of the entire run. The
length of the run in feet and the power factor of the run should be used in the
resistance equation below to calculate the value on the right side of the equation.

Resistance Equation

R = Resistance (refer to table below).

L = Length of run (or chain) in feet.
PF = Power factor of entire run (or chain).

R < L x PF

40,000

Where:

The required wire gauge should be chosen such that the resistance value is less than
the value calculated in the resistance equation. Refer to the following table.

Wire Gauge Values

RESISTANCE WIRE

GAUGE

4 16
6

18

10 20
15

22

13 Doubled

CAT5

8.7

Tripled CAT5

NOTE: All Cresnet wiring must consist of two twisted pairs. One twisted pair is the
+24V conductor and the GND conductor, and the other twisted pair is the Y
conductor and the Z conductor.

NOTE: When daisy-chaining Cresnet units, strip the ends of the wires carefully to
avoid nicking the conductors. Twist together the ends of the wires that share a pin on
the network connector, and tin the twisted connection. Apply solder only to the ends
of the twisted wires. Avoid tinning too far up the wires or the end becomes brittle.
Insert the tinned connection into the Cresnet connector and tighten the retaining
screw. Repeat the procedure for the other three conductors.

Advertising