Customer Responsibilities

Thank You

for purchasing a Sears water heatqjr.

Properly inscalled and maintained, it diould give you years of

trouble free service. If you should decide that you want the new

water heater professionally installed by Sears call the loti Sears

Service Center or any Sears store. They will arrange for prompt,

quality installation by Sears authorized contractors.

Abbieviations Found In This Instruction Manual

I.A.S. - International Approval Services, A Division of CSA

A.N.S.I. - American National Standards Institute

N.F.P.A. - National Fire Protection Agency

AWARNING

This gas-fired water heater is design certified by the

international Approval Services, A Division of CSA under

American National Standard/CSA Standard for Gas Water

Heaters ANS Z2I.I0.I • CSA 4.1 (latest edition). The
installation must conform with this manual. Local Codes

and with the latest edition of the National Fuel Gas Code
ANSIZ223.I,
This publication is available from your local government or

public library, gas company, or by writing NFPA,

Batterymarch Park, Quincy, MA 02269.

Rrad the “Safety Ptecautions” section, pages 2 through 4 of

this manual first and then the entire manual carefully. If you

don’t follow the safety rules, the water heater will not operate

properly. It could cause DEATH, SERIOUS BODILY

INJURY AND/OR PROPERTY DAMAGE

, ’l^is-manual contains instructions for the installation, opera­

tion, and maintenance

of

the gas-fired water heater. It also

contains warnings through out the manual that you must read

and be aware ofTAll warnings and all instructions are essential

CO

the proper operation of the water heater and your safety.

Since we cannot put everything on the first few pages, READ

THE ENTIRE MANUAL BEFORE ATTEMPTING TO

INSTALL OR OPERATE THE WATER HEATER.

The installation must conform with the instructions in this

manual; gas company rules; and Local Codes, or in the

absence of Local Codes, with the latest edition of the National

Fuel Gas code, ANSI Z223.I, also referred to as NFPA 54.

This publication is available from your local government or

public library or gas company or by writing NFPA,

Batterymarch Park, Quincy, M4.02269.

If after reading this manu^ you have any questions or do not

understand any portion of the instructions, call the Sears

Service Center.

^refully plan the place where you are going to put the water

heater. Correct combustion, vent action, and vent pipe instal­

lation are very important in preventing death from possible

carbon monoxide poisoning and fires.

famine the location to ensure the water heater complies with

the “Facts to Consider about the Location” section in this

manual.

For California installation this water heater must be braced,

anchored, or strapped to avoid falling or moving during an

earthquake. See instructions for correct installation proce­

dures. Instructions may be obtained from your local dealer,

wholesaler, public utilities or California Office of the State

Architect, 400 P Street, Sacramento, CA 95814.

Product Specifications

MODEL

NUMBER

TANK

CAPACITY

IN GALLONS

TYPE

OF

GAS

B.T.U.

RATE

RECOVERY RATE

GALS. PER HOUR

0WF RISE

MINIMUM

VENT

PIPE

DIMENSIONS DJ INCHES

DIAMETER

HEIGHT TO

JACKET TOP

153.330401

40

NATURAL

40,000

46.0

3" or 4"

18"

60"

153.330451

40

NATURAL

40,000

46.0

3" or 4"

18"

60"

153,330501

50

NATURAL

40,000

46.0

3" or 4"

20"

59

/

2

"

153.330551

50

NATURAL

40,000

46.0

3" or 4"

20"

59

/

2

"

153.330701

75

NATURAL

55,000

59.2

4"

24"

60"

153.330751

75

NATURAL

^ 55.000

59.2

4"

24"

60"

Advertising