Make certain this laundry center has the

correct burner for the type of gas in your

home. Burner information is located on

the rating plate in the door well of your
dryer, if this information does not agree
with the type of gas available, contact
your local Sears store or Sears Service

Center. Any change to the burner must
be made by a qualified installer.

Provide a gas supply of Vï-inch pipe

to your laundry center.

If your laundry center has been

converted to use L.P. gas, ^/e-inch

L.R-compatible copper tubing may be
used. If the total length of the supply
line Is more than 20 feet, use larger
pipe. Pipe joint compounds that resist

the action of L.P. gas must be used.

Do not use teflon tape.

This laundry center is equipped with its

own permanent, flexible gas connector,
design-certified by the American Gas
Association, for connecting the laundry
center to the gas supply line.

■ A combination of pipe fittings must

be used to connect the laundry center

to the existing gas line.

^/s-inch

male

threaded

connection

Va-inch

NPT

plugged

tapping

Reducer

or

connector

Vi-inch

gas

supply line

Gas

shut­

off valve

• The gas supply must have a shut-off

valve. The valve should be in the same
room as the laundry center, within six

feet. The location should be easy to

reach for opening and closing the valve.

• A Vs-lnch NPT plugged tapping,

accessible for test gauge connection,
must be installed immediately upstream
of the gas supply connection to the

laundry center.

• To ensure proper combustion and

ventilation, the laundry center instal­

lation should adhere to the minimum

recommended clearances. See page 18.

• For mobile home installation, see

page 19 for more instructions.

■ The laundry center must be discon­

nected from the gas supply piping

system during any pressure testing
of that system at test pressures in
excess of ' h psig.