STEP 1. Remove the red cap from

the gas pipe. Move the laundry center
to its final position.

STEP 2. Connect gas supply to laundry
center. Use a wrench to tighten. For
gas connections you must use pipe joint
compound resistant to the action of

L.P. gas. Apply pipe joint compound

to the non-flared male threads only.

There should be a natural loop in the

flexible gas connector. The flexible gas

connector must not be twisted, kinked
or attached with any sharp bends.

CONNECT LAUNDRY CENTER

TO GAS LINE

STEP 3. Open the shut-off valve in the

supply line. The valve is open when the

handle is parallel to the gas pipe.

OPEN

VALVE

STEP 4. Test all the connections by
brushing on a soapy water solution
(liquid detergent also works well).
Bubbles will show a leak. Correct

any leak found. Never test for gas

leaks with a flame.

CORRECT

WRONG