T & p valve and pipe insulation, Warning – Kenmore POWER MISER 153.320661 User Manual

Page 10

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

NOTE: To protect against untimely corrosion of hot and cold
water fittings, it is strongly recominencied that di-electric
unions or couplings be installed on this water heater when
connected to copper pipe.

Fit T & P valve insulation over valve. Make sure that the insulation
does not interfere with the lever of the T & P valve.

Secure all insulation using tape.

1, Look at the top cover of the water heater. The hot water outlet

is marked hot. Put two or three turns of teflon tape around

the threaded end of the threaded-to-sweat coupling and

around both ends of the 3/4” threaded nipple. Using flexible
connectors, connect the hot water pipe to the hot water outlet
of the water heater.

2. Look at the top cover of the water heater. The cold water inlet

is marked cold. Put two or three turns of teflon tape around

the threaded end of the threaded-to-sweat coupling and

around both ends of the 3/4” threaded nipple. Using flexible
connectors, connect the cold water pipe to the cold water
inlet of the water heater.

PIPE

INSULATION

NOTE: Your water heater is insulated to minimize heat loss

from the tank. Further reduction in heat loss can be
accomplished by insulating the hot water tines from the
water heater.

FIGURE 9A.

Temperature-Pressure Relief Valve

T & P Valve and Pipe Insulation

Remove insulation for T & P valve and pipe connections from

carton.

Fit pipe insulation over the incoming cold water line and the hot

water line. Make sure that the insulation is against the top
cover of the heater.

WARNING

Explosion Hazard

Temperature-pressure relief valve
must comply with ANSI A21.22
and ASME code.

Properly sized temperature-relief

valve must be installed in opening

provided.

Can result in overheating and
excessive tank pressure.

Can cause serious injury or death.

This heater is provided with a property certified combination
temperature - pressure relief valve by the manufacturer.

The valve is certified by a nationally recognized testing

laboratory that maintains periodic inspection of production of
listed equipment of materials as meeting the requirements for
Relief Valves and Automatic Gas Shut-off Devices for Hot Water
Supply Systems, ANSI Z21.22 • CSA 4.4, and the code
requirements of ASME.

If replaced, the valve must meet the requirements of local
codes, but not less than a combination temperature and
pressure relief valve certified as indicated in the above
paragraph.

The valve must be marked with a maximum set pressure not to

exceed the marked hydrostatic working pressure of the water
heater (150 psi = 1,035 kPa) and a discharge capacity not less

than the water heater input rate as shown on the model rating

plate.

For safe operation of the water heater, the relief valve must not
be removed from its designated opening nor plugged.

The temperature-pressure relief valve must be installed directly

into the fitting of the water heater designed for the relief valve.

10