This causes the water heater to become
much heavier than normal.
If spilled, could cause staining.

Mineral buildup or sediment may have accumulated in the old

water heater. This causes the water heater to be much heavier
than normal and this residue, if spilled out, could cause staining.

Facts to Consider About the Location

You should carefully choose an indoor location for the new
water heater, because the placement is a very important
consideration for the safety of the occupants in the building
and for the most economical use of the appliance. This water
heater is not intended for outdoor installation.

Whether replacing an old water heater or putting the water
heater in a new location, the following critical points must be
observed,

• The location selected should be indoors as close to and as

centralized with the water piping system as possible. This

water heater, as well as all water heaters, will eventually

leak. Do not install without adequate drainage provisions
so water flow will not cause damage.

CAUTIO

Property Damage Hazard

All water heaters eventually leak

Do not install without adequate drainage.

WATER HEATERS EVENTUALLY LEAK: Installation of the wafer
heater must be accomplished in such a manner that if the tank
or any connections should leak, the flow of water will not cause
damage to the structure. When such locations cannot be
avoided, a suitable drain pan should be installed under the
water heater. Drain pans are available at your local Sears stores.
Such drain pans must be piped to an adequate drain.

Water heater life depends upon water quality, water pressure
and the environment in which the water heater is installed.
Wafer heaters are sometimes installed in locations where
leakage may result in property damage, even with the use of a
drain pan piped to a drain. However, unanticipated damage
can be reduced or prevented by a leak detector or water shut­
off device used in conjunction with a piped drain pan. These

devices are available from your local Sears store, and detect
and react to leakage in various ways:

• Sensors mounted in the drain pan that trigger art alarm or

turn off the incoming water to the water heater when leakage
is detected.

• Sensors mounted in the drain pan that turn offthe water supply

to the entire home when water is detected in the drain pan,

• Water supply shut-off devices that activate based on the water

pressure differential between the cold wafer and hot water
pipes connected to the water heater.

I

CAUTIO

г

Insfallations in Residential Garages

• Water heater must be located in a

protective area.

INSTALLATION IN RESIDENTIAL GARAGES: The water heater
must be located and/or protected so it Is not subject to physical
damage by a moving vehicle,

• The location selection must provide adequate clearances

for servicing and proper operation of the water heater.

Insulation Blankets

Insulation blankets are available to the general public for
external use on electric water heaters but are not necessary

with this product. The purpose of an insulation blanket is to

reduce the standby heat loss encountered with storage tank
heaters. Your water heater meets or exceeds the National

Appliance Energy Conversation Act standards with respect to

Insulation and standby loss requirements, making an Insulation
blanket unnecessary.

Should you choose to apply an Insulation blanket to this heater,
you should follow these instructions below. Failure to follow

these instructions can result in fire, serious personal injury, or

death.

• Do not cover the temperature and pressure relief (T & P)

valve with an insulation blanket.

• Do not cover the instruction manual. Keep it on the side of

the wafer heater or nearby for future reference.

• Do obtain new warning and instruction labels from Sears

for placement on the blanket directly over the existing labels.

Facts to Consider About the
Convertible Lower Elernent

The Upper Element (if a double element model) Is a

conventional 3800 watt element which only operates at its rated

wattage on 240 volts. (See rating plate on the water heater).

The Lower Element of the water heater can be converted from

operation at 3800 watts to 5500 watts on a 240 volf system.

Read and follow water heater warnings and instructions. If
after reading these instructions in this manual, you do not
understand any portion, call Sears Service Center.