TROUBLESHOOTING

J

Start Up Conditions

THERMAL EXPANSION

CAUTIO

Property Damage Hazard

' Avoid water heater damage,

Install thermal expansion tank or device if necessary,

Contact qualified installer or service agency.

Wafer supply systems may, because of such events as high

line pressure, frequent cut-offs, the effects of water hammer
among others, have installed devices such as pressure
reducing valves, check valves, back flow preventers, etc,..to
control these types of problems. When these devices are not
equipped with an internal by-pass, and no other measures are

taken, the devices cause the water system to be closed. As
water is heated, it expands (thermal expansion) and closed
systems do not allow for the expansion of heated water.

The water within the water heater tank expands as if is heated
and increases the pressure of the water system. If the relieving
point of the water heater’s temperature-pressure relief valve is

reached, the valve will relieve the excess pressure. The

temperature-pressure relief valve is not intended for the
constant relief of thermal expansion. This is an unacceptable
condition and must be corrected.

it is recommended that any devices installed which could create
a closed system have a by-pass and/or the system have an
expansion tank to relieve the pressure built by thermal
expansion in the water system. Thermal expansion tanks are
available from Sears stores and through the Sears Service
Centers. Contact the local plumbing inspector, water supplier
and/or the Sears Service Center for assistance in controlling

these situations.

Thermal Expansion Tank Specifications

Model

Number

Tank

Capacity

In Gallons

Dimensions

in Inches

Pipe

Fitting

On Tank

Diameter

Length

153.331020

2

8 (203 mm)

12-3/4 (323 mm)

3/4” Male

153.331050

5

11 (279 mm) 14-3/4 (375 mm)

3/4” Male

Expansion Tank Sizing Chart

Expansion

Tank

Capacity

Needed

Inlet*

Water

Pressure

Water Heater Capacity (Gallons)

30

40

50

66

82

40psi

2

2

2

5

5

SOpsi

2

2

2

5

5

60psi

2

2

5

5

5

70psi

2

2

5

5

5

SOpsi

2

5

5

5

5

’‘Highest recorded inlet water pressure in a 24 hour period or
regulated water pressure.

NOTE: Expansion tanks are pre-charged with a 40 psi air
charge. If the inlet water pressure is higher than 40 psi, the
expansion tank’s air pressure must be adjusted to match
that pressure, but must not be higher than 80 psi.

WATER HEATER

m

WATER HEATER

COLD WATER

Possible noises due to expansion and contraction of some
metal parts during periods of heat-up and cool-down do not
represent harmful or dangerous conditions.

Operational Conditions

SMELLYWATER

In each glass-lined water heater there is installed one anode
rod (see parts section) for corrosion protection of the tank.
Certain water conditions will cause a reaction between this
rod and the water. The most common complaint associated

with the anode rod is one of a “rotten egg smell”. This odor is
derived from hydrogen sulfide gas dissolved in the wafer. The
smell is the result of four factors which must all be present for
the odor to develop:

A A concentration of sulfate in the supply water.

B. Little or no dissolved oxygen in the water.

C. A sulfate reducing bacteria within the water heater. (This

harmless bacteria is non-toxic to humans.)