Position the valve downward and provide tubing so that any
discharge will exit only within 6 inches (153 mm) above, or at
any distance below the structural floor. Be certain that no contact
is made with any live electrical part. The discharge opening
must not be blocked or reduced in size under any
circumstances. Excessive length, over 30 feet (9,14 m), or use
of more than four elbows can cause restriction and reduce the
discharge capacity of the valve.

CAUTIO

Water Damage Hazard

■ Temperature-pressure relief valve discharge

pipe must terminate at adequate drain.

No valve or other obstruction is to be placed between the relief

valve and the tank. Do not connect tubing directly to discharge
drain unless a 6 inch air gap Is provided. To prevent bodily

injury, hazard to life, or property damage, the relief valve must
be

allowed

to

discharge

water

in

quantities

should

circumstances demand. If the discharge pipe is not connected
to a drain or other suitable means, the water flow may cause
property damage.

The Discharge Pipe:

• Shall not be smaller in size than the outlet pipe size of the

valve, or have any reducing couplings or other restrictions.

• Shall not be plugged or blocked.

• Shall be of material listed for hot water distribution.

• Shall be installed so as to allow complete drainage of both

the temperature-pressure relief valve, and the discharge
pipe.

• Shall terminate at an adequate drain.

• Shall not have any valve between the relief valve and tank.

ADANGER

Water temperature over 125°F
(52°C) can cause severe burns
instantly resulting in severe injury
or death.

Children, the elderly, and the
physically or mentally disabled
are at highest riskfor scald injury.

Feel water before bathing or

showering.

Temperature limiting valves are

available.

Read instruction manual for safe

temperature setting.

The temperature-pressure relief valve must be manually
operated at least once a year. Caution should be taken to
ensure that (1) no one is in front of or around the outlet of the
temperature-pressure relief valve discharge line, and (2) the
water manually discharged will not cause any bodily injury or
property damage because the water may be extremely hot.

If after manually operating the valve, it fails to completely reset

and continues to release water, immediately close the cold
water inlet to the water heater, follow the draining instructions,
and replace the temperature-pressure relief valve with a new
one.

FIGURE 10.

Filling the Water Heater

CAUTIO

I

Property Damage Hazard

• Avoid water heater damage.

> Fill tank with water before operating.

Never use this water heater unless it is completely full of water.
To prevent damage to the tank and heating element, the tank
must be filled with water. Water must flow from the hot water

faucet before turning “ON” power.

To fill the water heater with water:

1. Close the water heater drain valve by turning the handle to

the right (clockwise). The drain valve is located on the lower
front of the water heater,

2. Open the cold water supply valve to the water heater.

NOTE: The cold water supply valve must be left open when
the water heater is in use.

3. To Insure complete filling of the tank, allow air to exit by

opening the nearest hot water faucet. Allow water to run until
a constant flow is obtained. This will let air out of the wafer

heater and the piping.