The water heater should be drained if being shut down during
freezing temperatures. Also, periodic draining and cleaning of
sediment from the tank may be necessary.

1

^

A WARNING

• Before removing any access

panels or servicing the water
heater, make sure the electrical
supply to the water heater is

turned “OFF".

• Failure to do this could result in

death, serious bodily injury, or
property damage.

1. Before beginning turn “OFF" the electric power supply to the

water heater.

2. CLOSE the cold water inlet valve to the water heater.
3. OPEN a nearby hot water faucet and leave open to allow for

draining.

4. Connect a hose to the drain vaive and terminate to an

adequate drain or outdoors.

5. OPEN the water heater drain valve to allow for tank draining.

NOTE: If the water heater is going to be shut down and
drained for an extended period, the drain valve should be left
open with hose connected allowing water to terminate to an
adequate drain.

6. Close the drain valve.
7. Follow “Filling the

Water

Heater” instructions in the

“Installation Instructions” section.

8. Turn “ON” power to the water heater.

CAUTIO

I

Improper installation and use may result

in property damage.

Fill tank with water before operation.

Never use this water heater unless it is completely full of water.

To prevent damage to the tank and heating element, the tank

must be filled with water. Water must flow from the hot water

faucet before turning “ON” power.

Thermostat Remoyal/Replaceinent

A WARNING

• Before removing any access

panels or servicing the water
heater, make sure the electrical
supply to the water heater is

turned “OFF".

w

• Failure to do this could result in

death, serious bodily injury, or
property damage.

1. Turn “OFF” the electrical power to the water heater at the

junction box.

2. Remove the access panel and the insulation cap with

handle.

3. Lift out the tab as shown below to unclip the terminal cover

from the thermostat. The terminal cover can now be removed
from the thermostat.

4. Remove the wires attached to the thermostat.

5. Remove the thermostat from behind the thermostat

bracket.

6. Disconnect wires from thermostat and slide out of the

bracket.

7. Place the new thermostat in the bracket making sure it fits

firmly against the tank.

8. Attach the wires to the new thermostat.

NOTE: Some of the terminals may require straight-in wiring
through an eye-opening. If wires are now looped, recut and
strip wire 3/8” to a straight length and insert.

9. Put plastic terminal cover back in place.

10. Replace the insulation cap with handle to cover the

thermostat.

11. Replace access panel, then turn the electric power on.

Element Cleaning/Repiacement

NOTE: These instructions are written for element cleaning and
element replacement for the lower element. If it is necessary to
clean or replace the upper element, then repeat these
instructions.

To remove the element from your tank in order to clean or
replace it;