step 7 -

ze, Test and Purge System

PRESSURE TEST THE SYSTEM
NOTE: Complete the sanitizing procedures on the pre­
ceding page before pressure testing.

To pressure test the system, complete the following
steps.

1. Turn the handle of the saddle valve counterclockwise

to open the valve. See Fig. 23.

2. Open the water supply valve to the Reverse Osmosis

System. See Figure 23.

3. Open the main water supply valve and several house

faucets. This will purge air from the house plumbing
and system. Close faucets when water runs smooth.
See Figure 23.
NOTE: If leaking occurs at the saddle valve, you may
need to tighten the saddle valve nut.

4. Pressure will start to build in the RO system in about 2

hours Carefully check all fittings and connections as
the system builds pressure. Check for water leaks. Fix
leaks if any are found. If problems exist, refer to the
troubleshooting chart or call the toll free number.

NOTE: When the system is first pressurized, water
may "spurt" from the faucet air gap hole until air is
expelled from the RO system.

Reverse

Osmosis

Faucet

Osmosis System

Figure 23

Please review the following operating features before
using your Reverse Osmosis System:

You will not have filtered water immediately. It may
take T3 hours to completely fill the storage tank and

create maximum flow from the Reverse Osmosis
faucet.

Water Pressure from the Reverse Osmosis faucet will be
less than your standard faucet.

Water will run to the drain while the Reverse Osmosis
system is producing water, even if you are not draw­
ing water from the Reverse Osmosis faucet. You may
hear a small quantity of water going to the drain for a
couple of hours. Water going to the drain will auto­
matically shut off when the storage tank is full.

PURGING THE SYSTEM
To purge the system, complete the following steps.

1. Open the Reverse Osmosis Faucet and let water

through the system for a 24 hour period.
NOTE: Water flow will be a slow trickle at this time.

2. Close the Reverse Osmosis faucet after the 24 hour

purging period is complete.

3. When the purging is finished, your Reverse Osmosis

system is ready for use.

NOTE: Codes in the state of Massachusetts require
installation by a licensed plumber and do not permit the
use of saddle valves.
If you live in the state of Massachusetts, review plumb­
ing code 248-CMR of the Commonwealth of

Massachusetts before proceeding with the installation.