Maintenance

CHANGE COLLET AND O-RING
1. Remove the collet and o-ring from the fitting with a

small screwdriver. Be careful not to scratch the inter­

nal walls of the collet port. See Figures 27 & 28.

2. Clean collet port, lubricate and insert the o-ring seal

into the bottom of the port. See Figures 27 & 28.

3. Push the collet inward until it locks in place. See

Figures 27 & 28.

Push o-ring seal into bottom of

port then follow with collet.

Fitting

O-Ring Seal

Collet

Change collet and o-ring

Figure 27

Collet (depress to
remove tubing)

Tubing

Disconnect Tubing

Figure 28

CHANGE BATTERY
When the coin battery is first applied at initial start up,
the LED indicator light will flash in a red, amber, green
sequence. All timers and counters are reset to zero. In
order to reset the time and gallon count feature, push the
the button on the P WA and hold until the LED flashes
and release. The battery needs to be replaced at the time
of filter replacement. Use only lithium batteries (CR 2032
or equivalent). Improper placement of battery could
damage electronics. Use care when inserting the battery
to align it correctly on PWA with the proper polarity.

- Reset button

Figure 29

NOTE: It is not recommended that the RO assembly be
opened. If this becomes necessary, pay careful attention
to the layout of the parts and the routing of the tubing.
It will be necessary to assemble the unit exactly as
shown for the system to fit together and function prop­
erly.