OPERATION

Warning: Before proceeding with
the following steps, ensure you

have read the L.P. Gas Cylinder
hose and Regulator sections of this

Assembly and Operation Manual.

Follow all directions under L.R Gas

Cylinder filling section of this
manual.

Middle Burner

Left Burner

Right Burner

Fig. 7

- HIGH

LOW

Fig. 8

LIGHTING

Prior to lighting your grill,

visually check all hoses
before each use for nicks,
cracking, abrasions or cuts.

If the hose is found to be
damaged in any way, DO
NOT USE YOUR GRILL.

A replacement hose and
regulator is required (see
‘PARTS LIST’ in back of
book).

IMPORTANT

• Always raise the grill lid

before lighting.

• Do not lean over the grill

when lighting the burner.

• Visually check the flames

every time you light your
grill (Figure 8). If the flame is abnormally small or smokey
yellow -- shut off the grill and check the venturi tubes for
blockage (see Figure 11 on pg. 27) or refer to the
Troubleshooting Guide.

On grills with Three burners, the right control knob operates
the right burner, the left knob operates the left burner, and the
center knob operates the center burner.

USING THE AUTO IGNITOR

Read these instructions before igniting.

1. Open lid during lighting.

2. Turn off all burners and close tank valve.
3. Open tank valve, wait 5 seconds.
4. Turn required burner knob to "IGNITE”.
5. You should hear a “clicking sound” indicating your electronio

ignition is activated.

6. If the burner does not light immediately (within four

seconds), turn burner control knob off and wait 5 minutes to
dear the gas.

7. Repeat steps 1 to 7. If burner still fails to light, refer to

Troubleshooting Guide to determine cause and solution,
or try the Match Lighting Procedure.

8. After grill lights, turn knob to desired cooking position.

MATCH LIGHTING PROCEDURE

TOpen the lid before lighting

2. Place an ignited lighter or lit match through the lighting hole.

(See Figure 9)

3. Push in and turn the LEFT burner control knob to ‘HIGH'.

The burner should light immediately (within four seconds). If

it does not, extinguish the lighter or match, turn the-control
knob to off, and wait 5 minutes to clear the gas.

4. Repeat steps 1 to 3. If burner fails to light, refer to the

Troubleshooting Guide to determine cause and solution.

5. Once left burner is lit push in and turn center burner knob

ffl^gh. Once it is lit, push in and turn right burner knob to

SIDE BURNER

1. Open L.P. cylinder.

2. Push in and turn the side burner control knob to “HI”.
3. Depending on which ignitor you have, turn or depress

ignitor. Repeat if necessary .

4. If burner does not light immediately (within four seconds),

turn the burner control knob off, and wait 5 minutes to clear
the gas.

5. Repeat steps 1 to 4. If burner still fails to light, refer to the

Troubleshooting Guide to determine cause and solution, or
try the Match Lighting Procedure above.

USING THE AUTO IGNITOR

1. Open tank valve, wait 5 seconds.

2. Turn required burner knob to

“IGNITE”.

3. You should hear a “clicking sound” indicating your

electronic ignition is activated.

4. If burner does not light immediately (within four seconds),

turn the burner control knob off, and wait 5 minutes to clear
the gas.

5. Repeat steps 1 to 5, if burner fails to light, refer to the

Troubleshooting Guide to determine cause and solution, or
try the Match Lighting Procedure above.

6. After grill lights turn knob to desired cooking position.

MATCH LIGHTING PROCEDURE

1. Place an ignited lighter or lit match near the ports,

approximately 1/2" (1.25 cm) from burner.

2. Push in and turn the side burner control knob to 'HIGH'. The

burner should light immediately (within four seconds). If it
does not, extinguish the lighter or match, turn the control
knob off, and wait 5 minutes for the gas to clear.

3. Repeat steps 1 and 2. If burner still fails to light, refer to the

Troubleshooting Guide to determine the cause and solution.

LOW HEAT OUTPUT

If the heat output from the burner(s) seems abnormally low.
It may be caused by the regulator flow-limiting device being
activated by a leak in the gas system, or improper lighting
procedures. If this is suspected, shut off the cylinder valve and
all burner valves. Perform a leak test to determine if a leak has
caused the flow-limiting device to activate. If the leak test is
negative, then carefully follow the lighting procedures step-by­
step, ensuring all valves (including tank) are off before starting.

RELIGHTING

If the burner flame goes out when your grill

is in operation, immediately turn off the
control valves. Wait five minutes for the gas
to clear before attempting to relight the
burner. If the problem persists, refer to the
troubleshooting guide

SHUTTING DOWN YOUR GRILL

1. Shut off L.P. cylinder valve or natural gas main shut-off valve.

2. Shut off burner control valves.
This sequence prevents residual gas from being left in the
system under pressure.

25