Installation Instructions (cont’d)

The convertible element is located, behind, the lower access

panel of the wmer hcatcj', 'Remove the two screws securing
the access panel, and remove panel.

3. Remove the insulation block and pad.

4. Lower Elemeut: Lift out the tab as shown to unclip the ter­

minal cover from the thermostat. The terminal cover can be
removed from the thermostat.

,5. Remove the screws from terminal 2 of the element, and. move

the looped end, of the wire asid e.

6. The buss bar is labeled 5.500 W. Place the buss bar over

terminals 2 and 3 with the 5.500 W visible. Install the extra
screw provided, into terminal 3.

The wire removed from terminal 2 has a looped end. It must

remain looped and now be placed (as shown) on top of the

buss bar, over the opening of terminal 2, and secured using

the remaining screw.

8. Tighten terminals 2 and 3 to ensure proper electrical

connection.

AWARNING

Failure to tighten terminal screws can cause a Pre which
can result In DEATH, SERIOUS BODILY INJURY, OR
PROPERTY DAMAGE.