Converting the Lower

Element (cont’d)

9. Replace tciminal cover on the thermostat, making sure the

notch is in place over the tab.

Installation Instructions (cont’d)

11, Replace the access panel.

Tït sj*a?¥a

W 7SP OF

AWÂRNING

Make sure the thermostat Is flush against the tank, the

terminal cover is in place, and the Insulation Is replaced.

Failure to do so can result in DEATH, SERIOUS BODILY
INJURY, OR PROPERTY DAMAGE,

10. Replace the insulation block and pad so that it completely

covers the thermostat and element.

12. Complete wiring to the water heater, or if completed, turn

“ON” electric power to the water heater after filling the
tank with water.

Bglllli

A CAUTION

Never use this water heater unless It Is completely full of

water. To prevent damage to the tank and heating ele­

ment, the tank must be filled with water. Water must

flow from the hot water faucet before turning “ON”

power.