Troubleshooting, Leakage checkpoints, Cont*d) – Kenmore POWER MISER 153.32154 User Manual

Page 24

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Troubleshooting

Leakage Checkpoints

Use this guide to check a “Leaking” water heater. Many suspect­
ed “Leakers” are not leaking tanks. Often the source of the water
can be found and, corrected.

rf you arc not thoroughly familiar with electric codes, the water
heater, and, safety practices, contact your local Scars Service
Center to check the water heater.

(cont*d)

A CAUTION

Read this manual first, then before checking the water
heater make sure the electric supply has been turned
“OFF”, and never turn the electric supply “ON” before

the tank is completely full of water.

^A) *Cond,cnsation may be seen on pipes in humid weather

or pipe connections may be leaking.

The primary anode rod, may be leaking.

Small amounts of water from temperature-pressure
relief valve may be due to thermal expansion or high

water pressure in your area.

*Thc temperature-pressure relief valve may be leaking at

the tank fitting.

The elements may be leaking at the tank fitting.

A WARNING

HAZARD

OF

ELECTRICAL

SHOCK!

Before

removing any access panels or servicing the water
heater, make sure the electrical supply to the

water heater is turned “OFF”, Failure to do this

could

result

in

DEATH,

SERIOUS

BODILY

INJUFTT, OR PROPEFtTY DAMAGE.

Turn electrical power “OFF”, remove access panels and
insulation block and, pad. If leaking around, elements,
follow

proper

draining

instructions

and

remove

clement. Reposition or replace gasket on dement. Place
clement into opening and tighten securely. Then follow
“Filling

the

Water

Heater”

instructions

in

the

“Installation Instructions” section.

Water from drain valve may be d,uc to the valve being

^ ^ opened, slightly.

*The drain val ve may be leaking at the tank fitting.

*Watcr in the water heater bottom or on the floor may

be from condensation, loose connections or the
temperature-pressure relief valve. DO NOT replace
the water heater until a full inspection of all possible

water sources is made and necessary corrective steps

taken,

I,cakagc from other appliances, wutcr lines, or ground
seepage should, also be checked,

NOTE; *To check where threaded portiou enters

tank, insert cotton swab bctwecii jacket opening and
fitting. If cotton is wet, follow “TImining” instme-
tions in the “Service and Adjustment” section and
then remoTO fitting. Put pipe dope or teflon tape on
the threads and replace. Then follow “PUliag the

Water

Heater”

instructions

in

the

“Installation

Instructions!” section.

24