Removing the old water heater, Awarning, A caution – Kenmore POWER MISER 153.32154 User Manual

Page 6: Installation instructions

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Installation Instructions

Removing the Old Water
Heater

^^Turn “OFF” electrical supply to the water heater.

©

Turn “OFF” the water supply to the

water heater at the water shutoff valve or
water meter.

Attach a hose to the water heater drain
valve and put the other end, in a floor
drain or outdoors. Open the water heater
drain valve. Open a nearby hot water
faucet which will relieve pressure in the
water heater and speed draining.

r^a. If you have copper piping to the water

heater, the two copper water pipes can be
cut with a hacksaw approximately

4"

away

from where they connect to the water
heater. This will avoid, cutting off the pipes
too short. Additional cuts can be made
later if necessary. Disconnect the tempera­
ture-pressure relief valve drain line, ^Ticn
the water heater is drained,, disconnect the
hose from the drain valve. Close the drain
valve. The water heater is now completely
disconnected and ready to be removed.

AWARNING

The water passing out of the drain valve be extreme­

ly hot. To avoid being scalded, make sure all connections

are tight and that the water flow is directed away from
any person.

Check again to make sure the electrical supply is
turned, “OFF” to the water heater. Then disconnect
the electrical supply connection from the water
heater junction box.

If you have galvanixcd, pipe to the water
heater, loosen the two galvanixcd, pipes

with a pipe wrench at the union in each

line. Also disconnect the piping remaining
to the water heater. These pieces should be
saved since they may be needed when
reconnecting

the

new

water

heater.

Disconnect the temperature-pressure relief
valve drain line. When the water heater is
drained, disconnect the hose from the
drain valve. Close the drain valve. The

water heater is now completely disconnect­

ed and ready to be removed.

A CAUTION

Mineral buildup or sediment may have accumulated in the

old water heater. This causes the water heater to be

much heavier than normal and this residue, if spilled out,

could cause staining.

Advertising