infiNET™ Switches

Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF

• The system tree of the control system displays the device in the appropriate

slot with a default MNET ID as shown in the following illustration.

C2Net Device, Slot 6, with infiNET Device

SIMPL Windows adds the selected infiNET device with a default MNET
ID. Following are the default MNET IDs used by SIMPL Windows for each
of the switch models:

• CLW-SW1RF: 07
• CLW-SW4RF: 09
• CLW-SWS1RF: 08
• CLW-SWS4RF: 0A

NOTE: The default MNET ID used by SIMPL Windows is different from
the default ID that is installed on an infiNET device when it ships from the
factory.

NOTE: If the default MNET ID is already in use, SIMPL Windows will
assign the next available MNET ID.

NOTE: infiNET repeaters such as the C2N-MNETRPT are not added in
SIMPL Windows as there is no control communication between a control
system and a repeater.

• If necessary, double click a device to open the “Device Settings” window

and change the MNET ID, as shown in the following figure.

“Device Settings” Window for the CLW-SW1RF

24

infiNET Switches: Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF

Operations Guide - DOC. 6397A