Npa stereo amplifier series – Ecler TP-NET User Manual
Page 13
13
NPA
STEREO AMPLIFIER SERIES
TYPE PARAM1 PARAM2
PARAM3 PARAM4
DESCRIPTION
SET
POWER
ON/OFF
Sets the Device Power status
PRESET
<Preset Number>
Sets the current PRESET
OLEVEL <Output
Channel>
<Level>
Sets the current LEVEL of an Output
Channel
OMUTE <Output
Channel>
YES/NO
Sets
the current MUTE status of an
Output Channel
SUBSCRIBE
ALL
Subscribes to all VU-meters
OVU
<Output Channel>
Subscribes to an Output Channel VU-
meter
UNSUBSCRIBE
ALL
Unsubscribe to all VU-meters
OVU
<Output Channel>
Unsubscribe to an Output Channel VU-
meter
DATA
POWER
ON/OFF
Shows the Device Power status
PRESET
<Preset Number>
Shows the current PRESET
OLEVEL <Output
Channel>
<Level>
Shows the current LEVEL of an Output
Channel
OMUTE <Output
Channel>
YES/NO
Shows
the current MUTE status of an
Output Channel
OVU
<Output Channel>
<Pre Vumeter Level>
<Post Vumeter Level>
Shows the VU-meter value of an Output
Channel
ALARM_PROTECT <Output Channel>
ON/OFF
Shows the Protect alarm status of an
Output Channel
ALARM_THERMAL <Output Channel>
ON/OFF
Shows the Thermal alarm status of an
Output Channel
ALARM_LOAD
<Output Channel>
ON/OFF
Shows the Load alarm status of an Output
Channel
ALARM_VOLTAGE ON/OFF
Shows the Voltage alarm status of the
Device
INFO_NAME
“<Device Name>”
Shows the Device Name
INFO_MODEL
<Device Model>
Shows the Device Model
INFO_VERSION
<Firmware Version>
Shows the Firmware Version
INFO_MAC
<Device MAC address>
Shows the Device MAC address
ERROR
<Error ID>
“<Error Description>”
Informs about an error