13

NPA

STEREO AMPLIFIER SERIES

TYPE PARAM1 PARAM2

PARAM3 PARAM4

DESCRIPTION

SET

POWER

ON/OFF

Sets the Device Power status

PRESET

<Preset Number>

Sets the current PRESET

OLEVEL <Output

Channel>

<Level>

Sets the current LEVEL of an Output
Channel

OMUTE <Output

Channel>

YES/NO

Sets

the current MUTE status of an

Output Channel

SUBSCRIBE

ALL

Subscribes to all VU-meters

OVU

<Output Channel>

Subscribes to an Output Channel VU-
meter

UNSUBSCRIBE

ALL

Unsubscribe to all VU-meters

OVU

<Output Channel>

Unsubscribe to an Output Channel VU-
meter

DATA

POWER

ON/OFF

Shows the Device Power status

PRESET

<Preset Number>

Shows the current PRESET

OLEVEL <Output

Channel>

<Level>

Shows the current LEVEL of an Output
Channel

OMUTE <Output

Channel>

YES/NO

Shows

the current MUTE status of an

Output Channel

OVU

<Output Channel>

<Pre Vumeter Level>

<Post Vumeter Level>

Shows the VU-meter value of an Output
Channel

ALARM_PROTECT <Output Channel>

ON/OFF

Shows the Protect alarm status of an
Output Channel

ALARM_THERMAL <Output Channel>

ON/OFF

Shows the Thermal alarm status of an
Output Channel

ALARM_LOAD

<Output Channel>

ON/OFF

Shows the Load alarm status of an Output
Channel

ALARM_VOLTAGE ON/OFF

Shows the Voltage alarm status of the
Device

INFO_NAME

“<Device Name>”

Shows the Device Name

INFO_MODEL

<Device Model>

Shows the Device Model

INFO_VERSION

<Firmware Version>

Shows the Firmware Version

INFO_MAC

<Device MAC address>

Shows the Device MAC address

ERROR

<Error ID>

“<Error Description>”

Informs about an error