Mimo88 digital matrix – Ecler TP-NET User Manual

Page 16

Advertising
background image

16

MIMO88

DIGITAL MATRIX

TYPE PARAM1 PARAM2

PARAM3 PARAM4

DESCRIPTION

DATA

PRESET

<Preset Number>

Shows the current PRESET

ILEVEL

<Input Channel>

<Level>

Shows the current LEVEL of an Input Channel

OLEVEL <Output

Channel>

<Level>

Shows the current LEVEL of an Output
Channel

XLEVEL

<Input Channel>

<Output Channel>

<Level>

Shows the current LEVEL for a Matrix point

IMUTE

<Input Channel>

YES/NO

Shows the current MUTE status of an Input
Channel

OMUTE

<Output Channel>

YES/NO

Shows the current MUTE status of an Output
Channel

XMUTE

<Input Channel>

<Output Channel>

YES/NO

Shows the current MUTE status for a Matrix
Point

IVU

<Input Channel>

<Pre Vumeter Level>

<Post Vumeter Level> Shows the VU-meter value of an Input Channel

OVU

<Output Channel>

<Pre Vumeter Level>

<Post Vumeter Level> Shows the VU-meter value of an Output

Channel

GPI

<Input>

<GPI Value>

Shows the current value of a General Purpose
Input

GPO

<Output>

<GPO Value)

Shows the current value of a General Purpose
Output

INFO_NAME

“<Device Name>”

Shows the Device Name

INFO_MODEL

<Device Model>

Shows the Device Model

INFO_VERSION

<Firmware Version>

Shows the Firmware Version

INFO_MAC

<Device MAC address>

Shows the Device MAC address

ERROR

<Error ID>

“<Error Description>”

Informs about an error

Advertising