Mac 10, Fan filter unit – Envirco MAC 10 IQ User Manual

Page 9

Advertising
background image

MAC 10

®

IQ

Fan Filter Unit

9

Innovators in Clean Air Technology | www.envirco.com | Operation & Maintenance

I n s t a l l a t i o n & S e r v i c e M a n u a l

Manual Control Mode:

In Manual control mode, the motor speed is set using the onboard potentiometer. Onboard potentiometer rotation is clockwise to

increase the motor output.
Analog Control Mode:

In ANALOG control mode, the motor output is set using an external 0-10 VDC demand signal.
Network Control Mode:

In NETWORK control mode, the motor output is set using MODBUS Register 2. Motor output is specified as a value from 0 to 100

representing a percentage of motor torque output. Each ENV1028 in a MODBUS network must be set to a unique address. The

address value is

set in binary format using the eight DIP switches of switch bank (S2). A maximum of 200 ENV1028 devices is

recommended per local area network(LAN). If an Envirco ACC Control Console is the MODBUS master, then addresses should be

assigned within the address range supported by the Control Console. Address zero should not be used as it is reserved for global

commands. Address switch settings are only checked by the ENV1028 at power-up. Power must be cycled (OFF/ON) before any

changes take effect.

1

2

ON

ADE02

1

3 4 5 6 7 8

O

N

2

Control Mode

DIP Switches

S1

Addess DIP Switches

S2

Note: Network mode can be configured using either DIP switch setting shown above. DIP switch pictorials are for

reference and may be labeled differently by the manufacturer.

Registers relevant to this mode (see chart on page 11):

Register 1 “Start/Stop” (R/W)

– To enable motor, write a value of 1; To disable motor, write a value of 0

Register 2 “Motor Set Speed” (R/W)

– Motor Target speed value. Values may be written from 0 to 100

Register 6 “RPM” (R)

– Motor RPM. Read from the motor

Register 12 “Actual Motor Speed Instruction” (R)

– Speed control signal applied to the motor by the ENV1028.

(R/W) = Read/Write, (R) = Read Only

Example of binary S2 switch settings

1

2

3

4

5

6

7

8

ON

DIP

1

 

1

2

3

4

5

6

7

8

ON

DIP

11

 

1

2

3

4

5

6

7

8

ON

DIP

21

1

2

3

4

5

6

7

8

ON

DIP

2

1

2

3

4

5

6

7

8

ON

DIP

12

1

2

3

4

5

6

7

8

ON

DIP

22

1

2

3

4

5

6

7

8

ON

DIP

3

1

2

3

4

5

6

7

8

ON

DIP

13

1

2

3

4

5

6

7

8

ON

DIP

23

1

2

3

4

5

6

7

8

ON

DIP

4

1

2

3

4

5

6

7

8

ON

DIP

14

1

2

3

4

5

6

7

8

ON

DIP

24

1

2

3

4

5

6

7

8

ON

DIP

5

1

2

3

4

5

6

7

8

ON

DIP

15

1

2

3

4

5

6

7

8

ON

DIP

25

1

2

3

4

5

6

7

8

ON

DIP

6

1

2

3

4

5

6

7

8

ON

DIP

16

1

2

3

4

5

6

7

8

ON

DIP

26

1

2

3

4

5

6

7

8

ON

DIP

7

1

2

3

4

5

6

7

8

ON

DIP

17

1

2

3

4

5

6

7

8

ON

DIP

27

1

2

3

4

5

6

7

8

ON

DIP

8

1

2

3

4

5

6

7

8

ON

DIP

18

1

2

3

4

5

6

7

8

ON

DIP

28

1

2

3

4

5

6

7

8

ON

DIP

9

1

2

3

4

5

6

7

8

ON

DIP

19

1

2

3

4

5

6

7

8

ON

DIP

29

1

2

3

4

5

6

7

8

ON

DIP

10

1

2

3

4

5

6

7

8

ON

DIP

20

1

2

3

4

5

6

7

8

ON

DIP

30

 

Advertising