Cisco XR 12000 Series User Manual

Page 38

Advertising
background image

2-8

Cisco XR 12000 Series Router SIP and SPA Hardware Installation Guide

OL-17438-04

Chapter 2 Overview: Cisco XR 12000 Series Router Shared Port Adapters

2-Port and 4-Port Channelized T3 to DS0 SPA Overview

The 2-Port and 4-Port Channelized T3 SPA LEDs are described in

Table 2-5

.

2-Port and 4-Port Channelized T3 SPA Interface Specifications

The framer processes incoming and outgoing T3 frames (cbit, m13/m23, and unframe) and E3 (g751,
g832) frames. The framer operates at T3/E3 line rates (44.2 44.736/34.368 Mbps) depending on the
mode in which it is configured.

Packet data is transported with a user-configurable encapsulation (such as Point-to-Point Protocol [PPP]
or High-Level Data Link Control [HDLC]), and is mapped to T3 and E3 frames. The encapsulations add
transport overhead to the packet of data frames before transporting, and are stripped when a packet is
transported to the far end.

The T3/E3 SPA interface is compliant with ANSI and Telco standards. The interface also provides
support for Management Information Base (MIB) RFC 2495, RFC 2496, and T1.231.

Note

The 2-Port and 4-Port Channelized T3 SPA supports Frame Relay Fragmentation (FRF.12) and Multilink
Fame Relay (MFR) features for Cisco IOS XR Software Release 3.6.0 and later releases.

2-Port and 4-Port Channelized T3 SPA Cables and Connectors

The interface connectors on the 2-Port and 4-Port Channelized T3 SPA are 75-ohm coaxial Siemax
types, with one connector and cable for transmit (TX) and one for receive (RX).

The following cables can be used with the 2-Port and 4-Port Channelized T3 SPA. The cables have BNC
connectors on one end and the Siemax connectors on the other.

CAB-T3E3-RF-BNC-M (T3 or E3 Cable, 1.0/2.3 RF to BNC-Male, 10 feet)

CAB-T3E3-RF-BNC-F (T3 or E3 Cable, 1.0/2.3 RF to BNC-Female, 10 feet)

CAB-T3E3-RF-OPEN (T3 or E3 Cable, 1.0/2.3 RF to BNC-Open end, 10 feet)

Table 2-5

2-Port and 4-Port Channelized T3 SPA LEDs

LED Label

Color

State

Meaning

C/A

Off

Off

Port is not enabled by software.

Green

On

Port is enabled by software, and there is a valid E3 or T3
signal without any alarms.

Amber

On

Port is enabled by software, and there is at least one alarm.

A/L

Off

Off

Port is not enabled by software.

Green

On

Port is enabled by software, loopback is off.

Amber

On

Port is enabled by software, loopback is on.

STATUS

Off

Off

SPA power is off.

Green

On

SPA is ready and operational.

Amber

On

SPA power is on and good, and SPA is being configured.

Advertising