Chamberlain EL25 User Manual

Page 14

Advertising
background image

Page 13

1 Press

2 Enter the Relay Number (1-4). Then (

#

)

3 Enter Activation Time (1-300 Seconds). Then (

#

)

Then

1 Press

2 Enter Door Number (1-4). Then (

#

)

3 Enter Relays to be Activated (0000-1111). Then (

#

)

Then

Example:

1

2

3

1

2

3

Assigns Relay “2” as a Shunt Relay

When Activated, the Relay Number “4” will activate for “30” seconds.

When a Resident uses a Valid Code at “Door 1”, Relay “1” and Relay “2” will Activate.

Example:

Example:

1

2

3

1 Press

Then

Set Each “

Relay Mode

” to get the Appropriate Response:

2 Enter the Relay Number (1-4). Then (

#

)

This is the amount of time (in seconds) the relay remains activated. This will define the amount of time a
door cycles (unlocks, then relocks) or how long the CCTV camera remains on after being activated.

Factory Setting: All Relays are set at 10 seconds

EL25 SetUp “Y

our Settings”

EL25 SetUp “Y

our Settings”

Set Each Relay's “

Activation Time

”:

3 Enter Relay Mode (0-5). Then (

#

)

0 =

Not Used

1 =

Strike

- controls a door/gate by unlocking/opening it.

2 =

Shunt

- bypasses the alarm under normal circumstances.

3 =

CCTV

- activates system's optional camera.

4 =

Alarm

- activates another device (siren).

5 =

Control

- controls another device (on/off light).

65

There are

5 different relay modes. The Relay Mode determines what the response will be when a valid access

code is entered (open a door, turn on an alarm, turn on a light then turn it off, turn on a CCTV, etc.).

Factory Setting: All Relays are Set at “1 - Strike”

Step 2

Step 3

66

When a

valid access code is used at an external access control device (Door), the EL25 can be set to activate

one or more relays.

Factory Settings: Door 1 Activates Relay 1; Door 2 Activates Relay 2;

Door 3 Activates Relay 3; Door 4 Activates Relay 4

Assign “

Each

” Door Number to One or More Relays:

Step 4

61

Note: A relay that controls a gate operator must be set to activate for 2 seconds.

0 = Deactivate , 1 = Activate (1st digit=Relay 4, 2nd digit=Relay 3, etc.)

Relay 4 Relay 3 Relay 2 Relay 1

Deact

Deact Activate Activate

Important:

All

through

eps

must be

performed for

EACH Door Number

assigned to the unit.

1

3

Important:

All

through

eps

must be

performed for

EACH Relay assigned

to the unit.

1

3

Important:

All

through

eps

must be

performed for

EACH Relay assigned

to the unit.

1

3

Advertising