Your” door settings, Your door settings, Door 1,2,3 – Chamberlain EL25 User Manual

Page 15: Page 14, When

Advertising
background image

Page 14

Sample: EL25 Controlling

1 Door

(Page 16)

EL25 SetUp “Y

our Settings”

EL25 SetUp “Y

our Settings”

When

“Your Door Settings”

or

Door 1,2,3

or

4

are referenced throughout this guide,

this completed chart will outline how your EL25 system will function.

Location

Relay Relay Mode

Relay Function

Relay Activation Time (Seconds)

Front Door

1

Strike

Unlocks Door

10 sec.

2

Shunt

Bypasses/Signals Alarm

40 sec.

Device

Main Keypad

(REX) Exit Request

Door 1

3

Alarm

Sounds a Siren

10 sec.

4

CCTV

Activates Camera

10 sec.

Sample: EL25 Controlling

2 Doors and a Vehicle Gate

(Page 16)

Location

Door No.

Door No.

Relay Relay Mode

Relay Function

Relay Activation Time (Seconds)

Front Door

Back Door

Gate Operator

1

Strike

Unlocks Door

10 sec.

2

Control

Turns on Security light

60 sec.

Device

Main Keypad and Postal Lock

Security Light

Wiegand Card Reader

Transmitter

Door 1

Door 2

Door 3

3

Strike

Unlocks Door

10 sec.

4

Strike

Opens Gate

10 sec.

Sample: EL25 Controlling

4 Doors

(Page 17)

Location

Relay Relay Mode

Relay Function

Relay Activation Time (Seconds)

Front Door (Entrance)

Front Door (Exit)

Back Door

Manager’s Door

1

Strike

Unlocks Door

10 sec.

2

Strike

Unlocks Door

10 sec.

Location

Relay

Relay

Mode

Relay Function

Relay Activation

Time (Seconds)

Device

Door No.

Device

Main Keypad

Wiegand Keypad

Wiegand Card Reader

Wiegand Card Reader

Door 1

Door 2

Door 3

Door 4

3

Strike

Unlocks Door

10 sec.

4

Strike

Unlocks Door

10 sec.

“Your” Door Settings

(See Tables below for reference)

Door No.

Sample: EL25 Controlling

Single Family Residence

(Page 18)

Location

Door No.

Relay Relay Mode

Relay Function

Relay Activation Time (Seconds)

Driveway

Pedestrian Gate

In EL25

1

Strike

Opens Vehicular Gate

10 sec.

2

Control

Turns on Security Light

10 sec.

Device

Main Keypad and

(REX) Exit Request

CCTV

Wiegand Card Reader

Door 1

Door 2

Door 3

3

Strike

Unlocks Pedestrian Gate

10 sec.

4

CCTV

Activates Camera

10 sec.

Sample: EL25 Controlling

Multi-Resident Apartment

(Page 19)

Location

Relay Relay Mode

Relay Function

Relay Activation Time (Seconds)

Front Door (Entrance)

Vehicular Gate

Pool Gate

Front Door (Entrance)

1

Strike

Unlocks Door

10 sec.

2

Strike

Unlocks Door

10 sec.

Device

Main Keypad

Transmitter and REX Exit Device

Wiegand Card Reader

Siren

Door 1

Door 2

Door 3

Door 4

3

Strike

Unlocks Door

10 sec.

4

Shunt

Bypasses/Signals Alarm

30 sec.

Door No.

Advertising