Programming

Number

Factory

Setting

Description of Task

Programming Procedure

***

12 # Enable/Disable True Anti-Passback (0 = disable;
1 = enable) # Enable/Disable Timed Anti-Passback (0
= disable; 1 = enable) #

15 # (0 – 1; 0 = one long ring, 1 = double ring) #

14 # (1 – 9) #

Disabled

11

Enable/Disable Unlock Time Zone

11 # (0 = disable; 1 = enable) #

Enable/Disable Real-Time Monitoring

Set Maximum Number of Rings
Allowed Before Aborting Attempt

Set “Strikes” and “Out”

Enable/Disable Direct Commands

24

24 # (0 = disable; 1 = enable) #

Enabled

Enable/Disable Access Granted Beeps

23

23 # (0 = disable; 1 = enable) #

Disabled

Enable/Disable Voice Mail

22

22 # (0 = disable; 1 = enable) #

Enabled

21

21 # (0 = disable; 1 enable) #

Enable/Disable the Telco Mode

Enabled

Enabled

10

Enable/Disable Do Not Disturb Schedule

10 # (directory code) # (0 = disable; 1 = enable) #

Disabled

20

20 # (0 = disable; 1 = enable) #

Set Microphone Volume

5

19

19 # (0 = mute; 1-10, 1 is low and 10 is high) #

Set Speaker Volume

5

18

18 # (0 = mute; 1-10, 1 is low and 10 is high) #

3 Errors

17

17 # (max errors, 0-5) #

Number of Rings Before Unit Answers

5 Rings

5 Rings

0 = One

Long Ring

16

Set Standard Single Ring or Double
Ring Response

15

14

16 # (0 – 15) #

Each unit in chain must have same setting

Set Anti-Passback Time

3 Minutes

9

Enable/Disable Call Waiting

9 # (0 = disable; 1 = enable) #

Enabled

Set Entry Code Length

7

7 # (3-9) #

4 Digits

Set Directory Code Length

6

6 # (1 or 2) #

2 Digits

Set Visitor Talk Time

5

5 # (15 – 250 seconds) #

60 Seconds

Enable/Disable Daylight Savings Time

4

4 # (0 = disable; 1 = enable) #

Enabled

Set the Clock

3

3 # yymmdd # (day of the week) # hhmm #

Set Unit ID Number and No. in Chain

2

2 # (unit ID number, 1-7) # (Number of Units in Chain, 1-7) #

Unit ID 1, Chain No. 1

Change or Verify the Unit's Password

1

1 # (1 to change; 2 to verify) # (six-digit code) #

000000

Exiting Programming Mode

Entering Programming Mode

0

0 #

***

(6 Digit Password)

13

Enable/Disable Anti-Passback

Disabled

12

13 # (1-60 minutes) #

The Pound Key (#) must be used as Data Field Separator and to Save Data at the end of the sequence.
Time must be entered using a 24-hour format

(8AM=0800, 3PM=1500 etc.)

2 Short Beeps:

Programming input is valid.

1 Long Beep:

Input is not valid.

If you make an error during an entry, press the asterisk key (

*

) to begin again.