8 CYLINDER


For an eight cylinder 4 magnets are required in total, positioned exactly 90

°

apart.














FIGURE 3: TYPICAL 8 CYLINDER APPLICATION






The ignition setup for the S1 needs to be configured in the following way:

Trigger Edge :

Rising

Trigger type :

Standard

Home Edge :

Falling


THE S2 HALL EFFECT SENSOR

The S2 sensor which is identified by a grey cable gland operates in the following way:

As a south pole passes the sensor face the signal in the secondary (PIN D) channel is
switched to a low state. As a north pole passes the sensor a low state will only occur on the
primary channel (PIN C).

The setup for this sensor is similar to the S1 except that one extra magnet is required as well
as the orientation being changed. The north pole of the magnet is used to generate the main
trigger while a south pole is used to generate the home or synchronisation pulse.