Haltech E6S User Manual
Page 122
122
8 CYLINDER
For an eight cylinder 4 magnets are required in total, positioned exactly 90
°
apart.
FIGURE 3: TYPICAL 8 CYLINDER APPLICATION
The ignition setup for the S1 needs to be configured in the following way:
Trigger Edge :
Rising
Trigger type :
Standard
Home Edge :
Falling
THE S2 HALL EFFECT SENSOR
The S2 sensor which is identified by a grey cable gland operates in the following way:
As a south pole passes the sensor face the signal in the secondary (PIN D) channel is
switched to a low state. As a north pole passes the sensor a low state will only occur on the
primary channel (PIN C).
The setup for this sensor is similar to the S1 except that one extra magnet is required as well
as the orientation being changed. The north pole of the magnet is used to generate the main
trigger while a south pole is used to generate the home or synchronisation pulse.