Odshr outdoor woodburning fireplace – CFM Corporation ODSHR42 User Manual

Page 15

Advertising
background image

15

ODSHR Outdoor Woodburning Fireplace

20002264

FP531
surround flush with
finish wall
12/20/01 djt

12"

(305mm)

Max.

12"

(305mm)

min.

*

1¹⁄₂"

12"

(305mm)

Max.

12"

(305mm)

min.

1¹⁄₂"

6"

(159mm)

Min.

1"

Mantel Clearance -
No Noncombustible Facing Material

Combustible Mantel

and Trim

Finished Wall

Header

Standoff

Noncombustible

Material

Surround

Face

Fireplace Opening

* Minimum width from top of sur-

round to bottom of screen rail

Combustible Mantel

and Trim

Finished Wall

Header

Standoff

Noncombustible

Material

Surround

Face

Fireplace Opening

Noncombustible Facing

Material

Must be sealed with non-

combustible material

Ledge Bracket

Finished Wall

2 x 4 Stud
Finished Wall

Must be sealed with

noncombustible material

Fireplace

Front

FP531

Fig. 24 Mantel clearances.

MA81

Fig. 25 Combustible mantel clearances.

MA81

rev. 8/5/97

rev. 4/18/01

1���"

Ref.

Combustible materials are

permitted within a shaded area

shown in Figure 27, titled

Minimum Wall Clearances.

���

* 12" (305 mm) from top of fireplace opening.
** 6" (154 mm) from top of fireplace opening.
(Noncombustible material must separate the
black face surround of the fireplace and any
combustible mantel material)