Installing Line for Gas Logs

CFM Corporation fireplaces are designed to accept a
1/2 inch gas line for installation of an approved gas ap-
pliance. (CFM Corporation manufactures a wide variety
of gas logs for use in Majestic Fireplaces units.)
Be sure to have the appliance installed in accordance
with building codes.
Gas connection may enter from either left or right side
of the fireplace.
Locate appropriate gas line in the outer casing of fire-
place and remove insulation from gas line tube. (Fig.
32)
From inside the fireplace, locate the knockout on the
firebrick -- be sure you are on the appropriate or "gas
line" side of the fireplace. Using a flat bladed screw-
driver or small chisel and hammer, carefully tap around
the knockout until it loosens and falls out.
Install 1/2 inch certified gas pipe through opening.
After gas pipe installation is complete, use insulation
that was removed from gas line tube to repack space
around the pipe. Material should be inserted from
outside of the fireplace and packed tightly to totally seal
between the pipe and tube.
NOTE: Gas pipe should not come in contact with
any wood structures until it has reached a point at
least one (1) inch away from fireplace side.
NOTE:
When installing an ANSI Z21.11.2 ventless ap-
pliance, the finishing material used for the mantel must
be rated at 250°F or greater.

FP1172
sealing detail 2
12/20/01 djt

2 x 4 Header

- Do Not Notch at

Ledge Brackets

Fig. 19

Wall Covering

Noncombustible

Decorative Facing

Seal All Cracks

Between Fireplace

Surround and Wall

Materials with

Noncombustible

Material

Noncombustible

Decorative Cover-

ing

Majestic Safety Strips

Must be Overlapped 1/2"

Min.

Seal Crack Between Fire-

place and Hearth Exten-

sion with Noncombustible

Material

FP1172

Fig. 31 Sealing detail.

Hearth

Extension

BTU input of a gas appliance installed in fireplace
should be rated less than 100,000 BTU/Hr.
Gas pipe installation is intended for connection to a
decorative gas appliance only when (1.) incorporating
an automatic shutoff device and (2.) complying with the
Standard for Decorative Gas Appliances for Installa-
tion in Vented Fireplaces (ANSI Z21.60) or CSA draft
requirements for Gas-Fired Log Lighters for Woodburn-
ing Fireplaces (Draft No. 4, August 1993).
Decorative gas appliance should be installed in accor-
dance with the National Fuel Gas Code, ANSI Z223.1/
NFPA 54 (latest edition).

CAUTION: WHEN USING DECORATIVE
GAS APPLIANCE, FLUE DAMPER MUST
BE SET IN FULLY OPEN POSITION. IF YOU

HAVE GLASS DOORS ON THE FIREPLACE,
THEY MUST ALSO BE FULLY OPENED.

WARNING: DO NOT OPERATE AN
UNVENTED GAS LOG SET IN THIS FIRE-
PLACE WITH THE CHIMNEY REMOVED.

WARNING: WHEN INSTALLING AN
UNVENTED GAS LOG SET, THE CFM
CORPORATION MODEL AH3244BK OR
AH3244PB 4" ADJUSTABLE HOOD MUST

BE USED.

OUTSIDE INSTALLATION: ONLY USE THE
OD30CFLN/P VENTED GAS LOG SET.

Only unvented gas log sets which have been found to comply
with the Standard for Unvented Room Heaters, ANSI Z21.11.2,
are to be installed in this fireplace.

If installing an unvented gas log set, refer to statement below:

1"

Min.

FP560SHR

SHR series

5/12/99 djt

1/2"

FP560SHR

Fig. 32 Gas line access.

Hole in Outer

Casing

Gas Line

Tubing

Ceramic

Knockout

Hole in

Outer

Casing

Supply

Line

Repack

Insulation

Ceramic

Knockout

(both sides)

Advertising