Vertical Communications TeleVantage 7.5 User Manual

Page 64

Advertising
background image

6-12

I

NSTALLING

I

NTEL

T

ELEPHONY

C

OMPONENTS

Connecting MSI/x analog station boards

1.

If the MS/x board is an ISA board:

Use the 50-pin RJ-21X cable to connect the board

to the port on the BCP connection panel port labeled

MSI Board

.

If the MS/x board is a PCI board:

Attach the 50-pin RJ-21X cable to the port on the

BCP connection panel port labeled

MSI Board

. Use the 37-pin D-shell adapter cable

to connect the board to the RJ-21X cable.

Note:

To avoid damaging the MSI/x board, do not plug trunk lines from the telephone

company into Station Line jacks S1-S24 on the BCP connection panel.

2.

Connect your phones:

Q

If you are setting up an analog system:

Using RJ-11 phone cables, connect your

analog phones to the jacks labeled

Station Lines

on the BCP connection panel. Use

jacks S1-S8 for 8-station boards, S1-S16 for 16-station boards, or S1-S24 for
24-station boards.

Assign your Operator to station S1 and other people who can handle a large volume
of calls to stations S2-S4. If the TeleVantage Server goes into failover, your first 4
analog trunks (T1-T4) will be routed directly to stations S1-S4. See “Failover
support” in Chapter 2 in Installing TeleVantage for more information.

Q

If you are setting up a T1, E1, or Internet telephony system:

Using RJ-11 phone

cables, connect your analog phones directly to the MSI/x board.

Connecting DISIx analog station boards

DISIx boards are connected to stations via an external Intel Dialogic DISIx station breakout box,
not via a BCP connection panel.

1.

Connect the board to the station breakout box using a 68-pin SCSI-3 cable.

2.

Using RJ-11 phone cables, connect your analog phones to the breakout box.