Connecting hdsi/x analog station boards – Vertical Communications TeleVantage 7.5 User Manual

Page 65

Advertising
background image

C

HAPTER

6. I

NSTALLING

I

NTEL

D

IALOGIC

B

OARDS

6-13

Connecting HDSI/x analog station boards

HDSI/x boards include an external station interface box (SIB) which provides the analog
interface for station activity.

The SIB sits between the HDSI/x board and the Intel Dialogic Business Communications
Platform (BCP) connection panel or breakout box. All connections are on the back of the SIB:

Note:

The maximum distance that the SIB can be from the HDSI/x board is 660 feet (201

meters.)

1.

Connect the board to the SIB using the 4 RJ-45 cables. Connect the top port of the
installed board to the left-most port on the back of the SIB, and so forth.

Note:

Cables must be connected in the correct order. If they are not connected

correctly, TeleVantage stations will be numbered incorrectly. Also, stations may not be
detected when you start the TeleVantage Server. See “TeleVantage Server fails to
detect some or all stations on HDSI/x analog station board” on page C-3
.

2.

Do one of the following:

Q

Connect the SIB to the BCP via the 5 RJ-21X ports on the back of the SIB. Be sure
to use an MSI -R power supply to power the BCP Panel so that it doesn’t go into
failover mode until power is out.

Q

Connect the SIB to the breakout box using an RJ-21X connector.

Advertising