Conversion to Natural Gas or LPG

Replacing the Burner Injectors

– Remove the pan supports, the burner caps and flame speaders.
– Using a wrench, substitute the nozzle injectors “J” (Figs. 19 - 20) with those most suitable for the kind

of gas for which it is to be used.

The burners are conceived in such a way so as not to require the adjustment of the primary air.

J

J

Triple Ring
burner

Auxiliary,
Semi-Rapid
and Rapid
burners

Fig. 19

Fig. 20

Table for the Choice of the Injectors

Cat: II 2H 3+

Burners

Nominal

Power

kW

Reduced

Power

kW

G30 - 28-30 mbar

G31 - 37 mbar

G20 - 20 mbar

Ø Injector

1/100 mm

Ø Injector

1/100 mm

Auxiliary (A)

1,00

0,30

50

72 (X)

Semi-Rapid (SR)

1,75

0,45

65

97 (Z)

Rapid (R)

3,00

0,75

85

115 (Y)

Triple Ring (TR)

3,50

1,50

95

135 (T)