Regulating the Burner Minimum Setting

When changing from one type of gas to another, the minimum tap output must also be correct, considering
that in this position the flame must be about 4 mm long and must remain lit even when the knob is turned
sharply from the maximum to the minimum position.

The adjustment is performed with the burner lit, as follows:
– Turn the knob to the minimum position.
– Remove the tap knob.
– Turn the screw “A” to the correct setting with a screwdriver (fig. 21).

For LPG, tighten the adjustment screw completely.

A

Fig. 21

Lubrication of the Gas Taps

The operations must be executed by a qualified technician.
IMPORTANT: All intervention regarding installation maintenance and conversion of the
appliance must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this obligation.