CDA HCG 931 User Manual

Page 8

Advertising
background image

8

Fig. 8

Burners and Grids

– These parts can be removed and cleaned with appropriate products.
– After cleaning, the burners and their flame spreaders must be well dried and correctly replaced.
– It is very important to check that the burner flame spreader and the cap have been correctly positioned.

Failure to do so can cause serious problems.

– Check that the electrode “S” (figs. 7-9) is always clean to ensure trouble-free sparking.
– Check that the sensor “T” (figs. 7-9) next to each burner is always clean to ensure correct operation of

the safety valves.

– Both the sensor and ignition plug must be very carefully cleaned.
– Note: To avoid damage to the electric ignition do not use it when the burners are not in

place.

Correct Positioning of the Burners (Auxiliary, Semi-rapid and Rapid burners)

– It is very important to check that the burner flame spreader “F” and the cap “C” have been correctly

positioned (see figs. 7 and 8). Failure to do so can cause serious problems.

F

C

Fig. 7

Ignitor “S”

Sensor “T”

Advertising