Appendix A. Specifications

46

220 Volt-AC Power Cord for Use in North America

The criteria for a U.S. and Canadian 220-volt AC power cord for the DAStape are as
follows:

• Power cord must have a molded NEMA 6-15P attachment plug on one end.

• Power cord must have a molded IEC 60320-type female connector to connect to the

DAStape unit.

• Cordage must be SJT type, three-conductor, 18 AWG minimum.

• Power cord must comply with local electrical code.

220 Volt-AC Power Cord for International Use

The criteria for an international 220-volt AC power cord are as follows:

• Power cord must have an attachment plug of the proper type, rating, and safety

approval for the intended country.

• Power cord must have a molded IEC 60320-type female connector to connect to the

DAStape.

• Cord must be a flexible, HAR (harmonized) type H05VV-F, three conductor, cord

with minimum conductor size of 0.03 square inches (1.0 square millimeter).

DAStape Environmental Specifications

Place the DAStape unit and media in a reasonably controlled environment that does
not exceed the environment limits listed in the table below.

To allow for proper cooling and to maintain the proper temperature of the DAStape,
leave at least six (6) inches of open space behind the unit.

Condition

Minimum

Maximum

Ambient Operating Temperature

2

°

C

30

°

C

Storage Temperature

-40

°

C 65

°

C

Relative Humidity (non-condensing)

20%

80%

Max. wet bulb temperature

N/A

26

°

C

Altitude

0 m (sea level)

3,000 m (9,842 ft)