Powering up the i/o modules – Avaya P460 User Manual

Page 84

Advertising
background image

Chapter 12

Troubleshooting the Installation

70

Avaya P460

Installation and Maintenance Guide

Powering up the I/O Modules

Problem

Possible Cause

Solution

I/O modules do not
power up

No Supervisor
module installed

Install supervisor module
(see “Supervisor Module
Installation“ on page 14)

Supervisor module
not functioning

Replace supervisor module

Insufficient Power
Budget

Add PSUs

Remove un-needed I/O
modules or
Disable power to the
appropriate I/O slots. See
the set slot power
command

Rearrange I/O Modules to
reflect priority

Power disabled to
I/O slot

Enable power to slot. See
the set slot power
command.

I/O modules powered
down automatically

Fan module removed
for more than five
minutes

Re-insert fan module
Power down chassis
Power up chassis

Advertising