Redundant power supplies – Avaya P460 User Manual

Page 53

Advertising
background image

Chapter 6

Maximizing Avaya P460 Availability

Avaya P460

Installation and Maintenance Guide

39

Redundant Power Supplies

The Avaya P460 supports automatic Power Supply redundancy and load-sharing.
Power supply redundancy is activated according to the number of PSUs and I/O
modules you have installed in the chassis.
Three PSUs are automatically configured in 2+1 redundancy mode.
If the installed power supplies can provide sufficient power for the switch, then an
additional power supply is automatically configured to operate in Redundancy
mode.
If the power budget requirement increases beyond the power available from the
non-redundant power supplies, then the additional power supply reverts to regular
mode.
In order to check whether power supply redundancy is operating, you can use the
show environment power

CLI command.

Note:

The “Total Power drawn from the system” always includes the power

reserved for two supervisor modules and the fan module.

P460 > show environment power

PSU1 Capacity: 300 Watts (48V @ 6.25 Amps)

PSU2 Capacity: none

PSU3 Capacity: none

PSUs Configuration: 1 PSU/s , no redundancy.

Total Power Available: 300 Watts (6.25 Amps @ 48V)

Total Power drawn from the system: 229 Watts (4.77 Amps @ 48V)

Remaining Power in the system: 71 Watts (1.48 Amps @ 48V)

Slot

Card-Type

Active

Enabled Draws(W)

Fault

----

--------------------

------- ------- ---------

-----

3

N

Y

0

4

avayaP460-M4648ML-T

Y

Y

48

5

N

Y

0

6

N

Y

0

*- 2 SPVs power consumption: 68(W) x 2, Fans power consumption: 45(W)