System Configuration

S900II

II – Instruction codes

16

01T01350_0

2.2.98

Type

of Instruction

Display

Codop (hexadecimal)

Examples

with Inputs (modulo 16)

= IN 000 (to 112)

D930 [oper. 16 bits]

> = IN 000 (to 112)

D931 [oper. 16 bits]

< = IN 000 (to 112)

D932 [oper. 16 bits]

AND IN 000 (to 112)

D933 [oper. 16 bits]

with Word (16 bits)

= WRD 0000 (to 4095)

D940 [oper. 16 bits]

> = WRD 0000 (to 4095)

D941 [oper. 16 bits]

< = WRD 0000 (to 4095)

D942 [oper. 16 bits]

AND WRD 0000(to 4095) D943 [oper. 16 bits]

INITIALIZATION

. 1 Operand

* on Bit –> 1

SET.BIT 032 (to 127)

D015 [oper. 16 bits]

on Bit –> 0

RST.BIT 032 (to 127)

D017 [oper. 16 bits]

* on Output –> 1

SET.OUT 000 (to 127)

D016 [oper. 16 bits]

on Output –> 0

RST.OUT 000 (to 127)

D018 [oper. 16 bits]

* on Word –> 0

RST.WRD 0000 (to 4095) D019 [oper. 16 bits]

* on WWord –> 0

RST.WWRD 00 (to 63)

D01D [oper. 16 bits]

* on Counter –> 0

RST.CNT 0000 (to 0015) D01A 00 [oper. 8 bits]

RST.CNT 0041 (to 9980)

D01A[oper. 8 bits] [oper. 8 bits]

. 2 Operands

* on Word (16 bits)

SET.WRD 0000 (to 4095) D600 [oper. 16 bits]

–> 1st Operand
with decimal value

= 0000 (to 9999)

D700 [oper. 16 bits]

+ 0000 (to 9999)

D701 [oper. 16 bits]

– 0000 (to 9999)

D702 [oper. 16 bits]

x 0000 (to 9999)

D703 [oper. 16 bits]

/ 0000 (to 9999)

D704 [oper. 16 bits]

AND 0000 (to 9999)

D705 [oper. 16 bits]

OR 0000 (to 9999)

D706 [oper. 16 bits]

with hexadecimal value

= 0000 (to FFFF)

D710 [oper. 16 bits]

+ 0000 (to FFFF)

D711 [oper. 16 bits]

– 0000 (to FFFF)

D712 [oper. 16 bits]

x 0000 (to FFFF)

D713 [oper. 16 bits]

/ 0000 (to FFFF)

D714 [oper. 16 bits]

AND 0000 (to FFFF)

D715 [oper. 16 bits]

OR 0000 (to FFFF)

D716 [oper. 16 bits]

Variable number

Counter number

PRG No.

SP No.

Variable number