System Configuration

S900II

IV – Variable addressing

25

01T01350_0

2.2.98

IV – 6. Counters

Each address corresponds to a 16 bit structure in the memory.

2 B4x

CNT0008

WRD0088

. values from 0000 to 9999 in decimal

. values from 0000 to FFFF in hexadecimal

b15

b0

x = bit number in hexadecimal (e.g.: CNT 0008, address = 2 B50).

– Standard counters – No. 0000 to 0015 (0x2B40 to 0x2B5E).

– Regular stacking counters – No. 0041 to 9960 (as from 0x2 B60).

– General stacking counters – No 0061 to 9980.

For the definition of these counters, see the Programming Level 2 manual, paragraph I6.

IV – 7. Timers

IV – 7. 1.End of timer for part program

Accessible in read and write.

TIM00

2 890

TIM01

2 891

TIM02

2 892

TIM03

2 893

TIM04

2 894

TIM05

2 895

TIM06

2 896

TIM07

2 897

TIM08

2 898

TIM09

2 899

TIM10

2 89A

TIM11

2 89B

TIM12

2 89C

TIM13

2 89D

TIM14

2 89E

TIM15

2 89F

2 897

TIM07

not used

Only the low order word is used

Number

(logical address)

Physical

address

Structures / Functions

IV – 7. 2.PLC timer

TIM00 to 15 = WRD 0064 to 0079 see chapter IV – 4.
Accessible in read and write.