System Configuration

S900II

V – CPU fault signalling

27

01T01350_0

2.2.98

V – 2. Fixed Leds

These signal a fault when powering up by giving the problem number in binary on the LEDs at the
bottom of the CPU, and the node number (if concerned) on the LEDs at the top if the pendant is not
functioning.

1 = Problem with recovering the parameters in Flashprom

2 = Problem during the opening of the PC link

3 = Problem during the opening of the EUROMAP 17 link

4 = Problem during the opening of the printer 2 link

5 = Problem during the opening of the CAN link

6 = Message not present in Flashprom

7 = Problem with the CPU’s RAM

8 = Problem with the Flashprom’s checksum

9 = Problem with the axes declared and the axes’ boards present

10 = The configuration has changed

11 = Problem during the initialization of the axes’ boards by the CPU

15 = Communication problem with the pendant during powering up. The CAN speed
may be changed by transfering the parameters with the PC at 2400 Bds, slave = 1.