16 bit user and system words - wrd, 32 bit user and system words - wwrd – Conair S900II User Manual

Page 26

Advertising
background image

System Configuration

S900II

IV – Variable addressing

24

01T01350_0

2.2.98

IV – 4. 16 bits user and system words – WRD –

WRD 0000

2AA0

WRD 0031

2ADF

WRD 0032

2AE0

WRD 0063

2B1E

WRD 0064

2B20

WRD 0079

2B3F

WRD 0080

2B40

WRD 0095

2B5F

WRD 0096

2B60

WRD 4096

3A9F

32 user Words (read/write) with no predefined functions.

B15

0

16 bit structure available

32 system Words (read only). For the definition of these
words, see the Programming Level 2 manual, paragraph
I4

16 user Words (read/write) supporting the standard
counters (CNT 00 to CNT 15).

4000 user Words (read/write) supporting the stacking
subroutine counters (CNT 0041 to CNT 9980).

16 user Words (read/write) supporting the PLC timers
(TIM 00 to TIM 15).

Number

(logical address)

Physical

address

Structures / Functions

IV – 5. 32 bit user and system words – WWRD –

WWRD 000

6230

WWRD 063

6327

64 user Words (read/write) with no predefined functions.

b31

0

32 bit structure available

WWRD 064

6328

WWRD 127

642C

64 system Words (read only). For the definition of these
words, see the Programming Level 2 manual, paragraph
I5

WWRD 0116

6400

Values for calculating the automatic anticipated restart.

WWRD 0117

6404

Values for calculating the automatic anticipated restart.
See chapter VI – page 28.

Specific words

Number

(logical address)

Physical

address

Structures / Functions