I – 2. Memory areas

I – 2. 1.Data saved in RAM (512 K x 8) 0 to 7 FFFF

Address in

Hexadecimal

Contents

00000

Variables used by Philips (BOOT)

027FF
02800

“Fixed” SEPRO variables, see table below for
details of the variables

0A4FF
0A500

SEPRO parameters in RAM

0B2FF
0B300

PRG storage area (128 K

×

8)

2A6FF
2A700

SEPRO variables / work tables

37FFF
38000

Temporary transfer area (128 K x 8)

57FFF
58000

Piles and heaps used by the ERM kernel

7FFFF

02800

En Ordre = RAM contents correct indicator (GIRLAFRIDOU).

02810

Bit_U_S = System and user bits table.

02890

Bit_Tpo = PLC timer bits table.

028A0

Imag_S = Images of the 255 ON/OFF outputs.

029A0

Imag_E = Image of the 255 ON/OFF inputs.

02AA0 Word_U = User words table (16–bit WORD).
02AE0

Word_S = System words table (see Programming Level 2 manual for description).

02B20

Tpo_Aut = PLC timers table.

02B40

Compt = Counters table (standard and stacking).

04AA0 Pile_Def = Pile of historic faults.
04BC0

Comptime = Times basic counter.

04BC4

Dir_RAM = PRG / PLC directory in editing area.

04C04

Dir_PP = PRG directory in save area.

05254

Dir_PLC = PLC directory in save area.

05710

Mod_PP = PRG directory in the module.

05D60

Mod_PLC = PLC directory in the module.

0621C

Tab_temps = Robot times table.

06230

WWord_U = Double words table (32 bits).

06430

Ram_PP = PRG editing area.

09430

Ram_PLC = PLC editing area.