Quick Start Procedure


This procedure outlines the steps to get the CellStat

TM

dialer operating in a typical

manner with a minimum of programming.

1. Plug the touch-tone telephone into the Dialer PHONE jack.
2. Connect external 12 VDC transformer to dialer power supply terminal block.

NOTE: External power required in order to configure the dialer from a local phone.

3. Verify that the AC POWER/CHARGING LED illuminates (green).
4. Turn ON the dialer switch. Wait about 30 seconds for the dialer to complete its power

on initialization sequence. Take the telephone off-hook. The OFF HOOK light
should be illuminated (yellow) indicating the unit is ready to accept touch-tone
commands from the local telephone.

5. Press the # key of your telephone. The Dialer will respond “Ready.”

NOTE: To start over, press the # key and listen for CellStat

TM

to speak, “Ready.”


6. Enter Telephone Numbers to Call upon Alarm.

z Enter **6np**, where n = 1,2,3,...8, is the dialer’s directory index of telephone

numbers, and p is the actual telephone number (including optional escape codes
of up to 60 digits). Example: The second phone number of the directory is 555-
1212. Enter **62 5551212**.

z The Dialer will respond, “Telephone number two is 5551212.”

z To cause the dialer to use its built-in cellular communications to make a voice

call, enter a *70 at the beginning of the telephone number. To cause an SMS text
message report to be sent, enter a *71 at the beginning of the telephone number.


7. Configure Input Normal States

z Enter **c3n, where c is the I/O channel (numbered 1 to 4 from left to right) and n

= 1 for NORMALLY OPEN, or 0 for NORMALLY CLOSED.


8. Record System and Alarm Voice Messages

System ID Voice Message:
z Enter **01 to record up to a 10 second system voice message. The dialer will

respond “Ready”.

z Speak your message clearly into the handset.
z The dialer will speak back the message after the 10-second recording interval.
z Repeat as necessary until you are satisfied with the recording.