Citizen Systems CBM-270 User Manual

Page 33

Advertising
background image

CBM-270 User’s Manual

settings by performing self-printing.

Jumper Wires

No.

Function

Short

Open

Upon

Shipment

J1

Short

J2

See Table 3

Short

J3

International character

Short

J4

Data bit length

7 bits

8 bits

Open

J5

Unused

Open

J6

Label detection

Black mark

Label interval

Open

J7

Unused

Open

J8

Com munic ation error mar k

Ignored

"?" printed

Open

J4: Serial interface only. Disabled for the parallel one.

J5

J7: Do not change the shipment settings.

Table 3

No.

USA

France

Germany

U.K.

Denmark-I

Sweden

Italy

Japan

J1

Short

Open

Short

Open

Short

Open

Short

Open

J2

Short

Short

Open

Open

Short

Short

Open

Open

J3

Short

Short

Short

Short

Open

Open

Open

Open

CAUTION:

1) Never change the settings of the jumper wires.
2) If you want to change their settings, consult us.
3) Never disassemble the printer body. It could cause trouble, etc.

Advertising