Esc c 5 n, Esc d n – Citizen Systems CBM-270 User Manual

Page 63

Advertising
background image

CBM-270 User’s Manual

ESC c 5 n

[Function]

Enabling/Disabling the panel switches

[Code]

<1B> H <63> H <35> H <n>

[Range]

0

n

255

[Outline]

Selecting the LF switch valid/invalid.

"n" is valid only in the lowest bit (n0).

"n" bit means the followings.

n0

Condition

0

LF SW valid.

1

LF SW invalid.

[Caution]

When the panel switch is disabled with this command, the LF switch is disabled. Therefore,

the paper cannot be fed by operating the LF switch.

[Default]

n = 0

[Sample Program]

LPRINT CHR$ (&H1B) ; "c5" ; CHR$ (0) ;

••••••••

When enabling the LF switch

LPRINT CHR$ (&H1B) ; "c5" ; CHR$ (1) ;

••••••••

When disabling the LF switch

ESC d n

[Function]

Printing and feeding the paper by n lines

[Code]

<1B> H <64> H <n>

[Range]

0

n

255

[Outline]

Prints data inside the buffer and feeds paper by n lines.

Specified line does not remain.

The beginning of the line is to be considered as the next printing start position.

[Default]

The initial value is not defined.

[Sample Program]

LPRINT "AAAAA"

LPRINT CHR$ (&H1B) ; "d" ; CHR$ (2) ;

LPRINT "AAAAA" ; CHR$ (&HA) ;

END

[Print Results]

Advertising