6.3

Input and Output Signals

6.3.1

Input and Output Signals

(1) Input signals to the printer

DATA

: 8-bit parallel signal (Positive logic)

STROBE

: Strobe signal to read the 8-bit data (Negative logic)

RESET

: Signal to reset the entire printer (Negative logic); 1 ms or more

(2) Output signals from the printer

ACK

: 8-bit data request signal. A pulse signal to be output at the end of the BUSY signal

(Negative logic)

BUSY

: Signal to indicate that the printer is busy. Input new data when it is "Low." (Positive

logic)

FAULT

: Turned to "Low" when the printer has an alarm. At this time, all the control circuits in

the printer stop. (Negative logic)

PE

: Output if the printing paper has run out or is running out. (Positive logic)

(3) Power source and the related

+5 V DC

: 5 V output pulled up by a 10k

resistor

GND

: Common ground for the circuits

6.3.2

Electrical Characteristics