VL6C+ ™ SPOT LUMINAIRE USER MANUAL

ROUTINE MAINTENANCE

Replacing the Lamp

Parts:

71.2528.0700.0

LAMP, MSR 700W

Tools:

Screwdriver, #2 Phillips
Screwdriver, slotted

WARNING:

Remove power from luminaire before performing any maintenance procedures.

CAUTION:

Refer to

"Proper Lamp Servicing and Operation"

on page 43 before handling the lamp.

To replace lamp:

Step

1. At APS6 module, remove power from lamp and allow lamp to cool for at least 5 minutes.

Step

2. Remove power from luminaire.

Step

3. At backcap, loosen captive knob and slide backcap out of head assembly (it will remain attached by tether).

(Figure 4-1.)

Step

4. Remove lamp by pulling straight out of socket.

Step

5. Noting polarity of lamp to socket, install new lamp by pressing firmly into socket, making sure it is fully

seated.

Step

6. Align guide rods in guide holes and slide backcap into head assembly.

Step

7. Ensure that backcap is fully seated in rear chassis and re-tighten captive knob.

Step

8. Align lamp. (Refer to next procedure.)

Figure 4-1: Lamp Replacement

Head Assembly

Guide Rods

Lamp

Backcap

CAUTION:

Do not touch lamp or

reflector with bare fingers.

CAUTION:

Allow lamp to cool

before servicing.

Captive
Knob