View machine info hotcup operators’ guide – CMS Products 674 User Manual

Page 94

Advertising
background image

View Machine Info

HotCup Operators’ Guide

6740001

88

November, 2007

DBV COMM

Incomplete bill validator communications — check harness.

DBV MOTOR

One of the motors has failed. The unit will disable itself until the error is
corrected. Check for bill stuck in the acceptance path. If no bill is present,
replace the validator. Cycle machine power OFF and then ON.

DBV SENSOR

One of the sensors in the bill validator has failed. The unit will disable itself
until the error is corrected. Check for bill stuck in the acceptance path. If no
bill is present, replace the validator. Cycle machine power OFF and then
ON.

DBV JAM

A bill is jammed in the acceptance path. The unit will disable itself until the
error is corrected. Remove bill stuck in the acceptance path. Cycle
machine power OFF and then ON.

DBV STACKR

The stacker is open or removed. The unit will disable itself until the error is
corrected. Install the stacker correctly.

CHK PRICE

Price error detected and changed to maximum - check prices.

NONE READY

All selections are reported out of service.

pV.ERR CUP 1

Cup ring 1 is out of service due to a PosiVend™ error.

pV.ERR CUP 2

Cup ring 2 is out of service due to a PosiVend™ error.

pV.ERR PCB

PosiVend™ is ON but not working. The last calibration sample was 255.
Check that the PosiVend™ PCB is present at J34.

PV.ERR SNSR

PosiVend™ is ON but not working. The last calibration sample was £50.
Check for a blocked sensor or disconnected harness.

AJP.TMR1 XX

PosiVend™ is active and ring 1 anti-jackpot timer is ON. XX is a value
between 1 and 99 in minutes.

JP.TMR2 XX

PosiVend™ is active and ring 2 anti-jackpot timer is ON. XX is a value
between 1 and 99 in minutes, and represents the amount of time left on the
anti-jackpot timer for this cup ring.

ANo brewer

Brewer is missing or malfunctioning.

Brewer.err

The brewer is in an incorrect position.

Brewer jam

The brewer has not reached an appropriate position within a certain time-
out period. Check for a physical jam or a motor stall condition.

Reset brwr

The brewer is clamped and not vending, or is not in a brewer test mode.
Close the door (if open), or run a brew test.