Test the brewer, Test various sensors and switches, Rinse all mixing bowls – CMS Products 674 User Manual

Page 85: Hotcup operators’ guide testing

Advertising
background image

HotCup Operators’ Guide

Testing

November, 2007

79

6740001

TEST THE BREWER

a. Press

, then press

until the display shows

BREW TEST

.

b. Press

to test each brewer position:

WARNING

Keep away from the brewer mechanism while it is operating.

Coming into contact with moving parts could injure you.

i.

BREW CLMPD

The brewer is in the brew position.

ii.

BREW HOME

The brewer is in the HOME position.

c. CONTINUE.

TEST VARIOUS SENSORS AND SWITCHES

a. Press

, then press

until the display shows

IN.XXXXXX

. The X's in the

display will be replaced by the following place holders:

M K P H L 1

, defined as follows:

M = mug/cup sensor (if equipped)

K = freevend keyswitch

P = waste pail switch

H = high water tank level switch

L = low water tank level switch

1/2 = ring 1/2 cup sensor switch

b. Actuate each switch or sensor to test its function. As you actuate each input, the display

element representing that switch blinks on. Releasing the switch causes that element to blink
off again, and be replaced by a dash.

c. CONTINUE.

RINSE ALL MIXING BOWLS

WARNING

Very hot water will be dispensed in this test. Coming into contact

with hot water is dangerous!

a. Press

, then press

until the display shows

BOWL RINSE

.

b. Press

to rinse all bowls.

RINSING

is displayed.

c. CONTINUE.

Advertising
This manual is related to the following products:

676