Solvline Eddy Serial Ver 2.1.0.3 User Manual

Page 57

Advertising
background image

Chapter7. Appendix

57

def v1readwrite
[enable, disable]

Disable

SNMP V1/V2 Attributes can read and write by SNMP
Agent.
In order to read attributes only change the feature to
"ReadOnly.‛
In order to read and write attributes change the feature to
"ReadWrite.‛
(Options : ReadOnly/ ReadWrite)

def v3readwrite
[enable, disable]

Disable

SNMP V3 Attributes can read and write by SNMP Agent.
In order to read attributes only change the feature to
"ReadOnly.‛
In order to read and write attributes change the feature to
"ReadWrite.‛
(Options : ReadOnly/ ReadWrite)

def v3username
[string]

eddy

Configure the Username when use SNMP V3.

def v3password
[string]

none

Configure the password when use SNMP V3.

def trapip
[address]

0.0.0.0

Configure the server IP address which receives the TRAP
information.

def trapoprt
[Socket No.]

162

Configure the server Port which receives the TRAP
information.

def trap_reset
[enable, disable]

Enable

If Enable is selected, inform the "System reset info".

def trap_connect
[enable, disable]

Disable

If Enable is selected, inform the "Serial Port opened info".

def trap_disconnect
[enable, disable]

Disable

If Enable is selected, inform the "Serial Port Closed info".

def landhcp
[enable, disable]

Enable

If Enable is selected, DHCP server service will be enabled
on the LAN port.

def lanip <IP
Address>

10.10.1.1

Set the IP address on the LAN port.

def lanmask
<Subnet Mask>

255.255.255.0

Set the subnet mask address on the LAN port.

def lanstart <IP
Addrss>

10.10.1.2

Set the start address for the DHCP range on the LAN port.

def lanend <IP
Address>

10.10.1.30

Set the end address for the DHCP range on the LAN port.

def leasetime
<msec>

180

Set lease time for DHCP.