Jumper Settings

In order for the 810/825 to operate as desired hardware, Jumpers must be set properly.
Most of the jumper setting’s are set correctly at the factory and never need to be altered, but
occasionally there is a need to alter a jumper setting, therefore they are shown below

Jumper List

Number Name

Setting Description


J8

NTEP/CTS

NTEP

Enable

NTEP

operation

CTS

Enable

CTS

flow

control

J9

RAM

8K

Use

8K

RAM

32K

Use

32K

RAM

J10

EPROM

256

Use

27C256

EPROM

512 Use

27C512

EPROM

J12

Back

light

On

Back

light

on

Off

Back light off

J13*

Load Cell Sense (+)

On

Not using load cell sense wires (+)

Off

Using

load

cell

sense

wires

(+)

J14*

Load Cell Sense (-)

On

Not using load cell sense wires (-)

Off

Using

load

cell

sense

wires

(-)


*NOTE: Jumpers “J13” and “J14” must both be either connected or disconnected to avoid
improper weighing and/or possible damage to the indicator.